PACKAGE TERMINAL AIR CONDITIONER/ HEAT PUMP Installation Manual and Owners Manual


PACKAGE TERMINAL AIR CONDITIONER/ HEAT PUMP Installation Manual and Owners Manual cover page
Often during installation or repair it is possible … on or near the head of the power cord as part of the normal troubles hooting procedure. WARNING T HIS AIR CONDITIONER IS NOT … PTACATTENTION INSTALLING PERSONNEL As a professional installer you have an obligation to know the product better than the customer. This includes all safety precautions and related items. Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings. Often during …

LCDI or AFCI Power Cords - Underwrites Laboratories and the National Electric Code (NEC) now require power cords that sense current leakage and can open the electrical circuit to the unit on units rated at 250 volts or less. In the event that unit does not operate, check the reset button located on or near the head of the power cord as part of the normal troubleshooting procedure. LCDI power Cord • Automatic 3-minute compressor lockout - After the compressor cycles off, it will not restart for three minutes. • Automatic 2nd stage electric heat - If the room temperature falls to 4°F below the set point temperature, the reverse cycle heat is shut off and the electric strip heat is turned on. • Automatic freeze protection - Whenever power is supplied to the unit and the master switch is in the ON position, automatic freeze protection is active. If the unit senses temperature below 40°F, the fan motor and electric strip heat are turned on. Freeze protection can be turned off, if required. • Random restart delay - To help eliminate power surges after a power outage, the unit is equipped with a two to four minute random restart delay feature. Whenever the unit is plugged in with the master switch turned on and the mode switch set in the cool or heat mode, a random restart will occur. A random restart condition can be avoided by setting the mode switch in the fan only or off position before applying power to the unit. • Fuse holder - On all 265 volt units, fuse holders are factory installed. Check for blown fuse if unit does not operate. Fuse holder is located behind the front. Replacement fuses may be purchased from the Parts Department or contact your sales representative for part numbers…. SLEEVE STIFFENER AND REAR CLOSURE PANEL REMOVAL Before the chassis can be installed in the wall sleeve, the sleeve stiffener and the rear closure panel must be removed. 1. Remove the zigzag folded cardboard sleeve stiffener. 2. Remove the rear closure panel by folding the four flaps. 3. Grasping the top and bottom flanges of the rear closure panel pull the entire panel out diagonally from one side. DRAIN KIT INSTALLATION ( Optional Accessory ) During normal reverse cycle heating operation, condensate water will drain out of the rear of the wall sleeve. If this water is objectionable, a drain kit should be installed. The drain kit has provisions for draining the water from either the right or left side of the sleeve externally or from the bottom of the sleeve internally.

Download PACKAGE TERMINAL AIR CONDITIONER/ HEAT PUMP Installation Manual and Owners Manual.Pdf

Leave a Reply